319 Electrical Specifications |
|
Current AC |
|
Range |
40.00 A, 600.0 A, 1000 A |
|
Resolution |
0.01 A, 0.1 A, 1 A |
|
Accuracy |
1.6% ± 6 digit (50-60 Hz) {40 A} |
|
|
2.5% ± 8 digit (60-500 Hz) {40 A} |
|
|
1.5% ± 5 digit (50-60 Hz) {600/1000 A} |
|
|
2.5% ± 5 digit (60-500 Hz) {600/1000 A} |
|
Crest Factor add 2% into spec for CF > 2 |
3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A |
|
AC response |
rms |
|
|
Current DC |
|
Range |
40.00 A, 600.0 A, 1000 A |
|
Resolution |
0.01 A, 0.1 A, 1 A |
|
Accuracy |
1.6% ± 6 digit (40 A) |
|
|
1.5% ± 5 digit (600/1000 A) |
|
|
Voltage AC |
|
Range |
600.0 V |
|
Resolution |
0.1 V |
|
Accuracy |
1.5% ± 5 digit (20-500Hz) |
|
AC response |
rms |
|
|
Voltage DC |
|
Range |
600.0 V |
|
Resolution |
0.1 V |
|
Accuracy |
1% ± 4 digit |
|
|
Resistance |
|
Range |
400.0 Ω |
|
|
4000 Ω |
|
Resolution |
0.1 Ω |
|
|
1 Ω |
|
Accuracy |
1% ± 5 digit |
|
|
Continuity |
|
|
Inrush |
|
|
Frequency |
|
Range |
5.0 - 500.0 Hz |
|
Accuracy |
0.5% ± 5 digit |
|
Trigger Level |
10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A |
|